Menu
Your Cart

Fluke 101 Digital Multimeter

Fluke 101 Digital Multimeter
Fluke 101 Digital Multimeter
Fluke 101 Digital Multimeter
Fluke 101 Digital Multimeter
Fluke 101 Digital Multimeter
Fluke 101 Digital Multimeter
Fluke 101 Digital Multimeter
  • Stock: In Stock
  • Model: Fluke 101
  • Weight: 0.55kg
People Interested: 10232
Rs.3,800
Ex Tax: Rs.3,800

Specifications: Fluke 101 Digital Multimeter

Electrical Specifications
V AC (40-500Hz)Range600.0 mV
6.000 V
60.00 V
600.0 V
Resolution0.1 mV
0.001 V
0.01 V
0.1 V
Accuracy3.0%±3 digit
1.0%±3 digit
V DCRange6.000 V
60.00 V
600.0 V
Resolution0.001 V
0.01 V
0.1 V
Accuracy0.5%±3 digit
Resistance OhmsRange400.0 Ω
4.000 kΩ
40.00 kΩ
400.0 kΩ
4.000 MΩ
40.00 MΩ
Resolution0.1 Ω
0.001 kΩ
0.01 kΩ
0.1 kΩ
0.001 MΩ
0.01 MΩ
Accuracy0.5 %±3 digit
0.5 %±2 digit
0.5 %±2 digit
0.5 %±2 digit
0.5 %±2 digit
1.5%±3 digit
CapacitanceRange50.00 nF
500.0 nF
5.000 μF
50.00 μF
500.0 μF
1000.0 μF
Resolution0.01 nF
0.1 nF
0.001 μF
0.01 μF
0.1 μF
1 μF
Frequency
(10 Hz – 100 kHz)
Range50.00 Hz
500.0 Hz
5.000 kHz
50.00 kHz
100.0 kHz
Resolution0.01 Hz
0.1 Hz
0.001 kHz
0.01 kHz
0.1 kHz
Duty CycleRange0.1 % to 99.9 %
Resolution0.1 %
General Specifications
CAT RatingCAT III 600 V
V AC Range600.0 V
V DC Range600.0 V
Ohms Range40.00 MΩ
Auto ShutoffY
ContinuityY
Capacitor100.0 μF
Frequency100.0 kHz
HoldNo
Duty CycleYes
Size130 mm x 65 mm x 27mm 
Weight160 g
BatteryTwo AAA
Warranty1 year
Environmental Specifications
Operating Temperature0 °C to +40 °C
Storage Temperature-30 °C to +60 °C
Operating HumidityNon condensing (<10 °C)
<=90% RH (at 10 °C to 30 °C)
<=75% RH (at 30 °C to 40 °C)
(Without Condensation)
Operating Humidity, 40 MΩ80% RH 10 °C to 30 °C, 70% RH 30 °C to 40 °C
Operating Altitude2,000 meters
Storage Altitude12,000 meters
IP RatingIP 40 per IEC 60529
Vibration RequirementsMIL-PRF-28800F, Class 2
Drop Test Requirements-10°C and 1 meter to surface, per IEC-61010-1, and Fluke SOP 39.1 for portable Hand-held equipment
Shipping container drop per Fluke SOP 39.
EMI, RFI, EMCMust meet all applicable requirements in
IEC/EN 61326-1
Absorption/CorrosionPer Fluke SOP 39.1
Temperature CoefficientsAdd 0.1 x specified accuracy for each degree C above 28 °C or below 18 ºC




Features:


  1. Basic dc accuracy 0.5%
  2. CAT III 600 V safety rated
  3. Diode and continuity test with buzzer
  4. Small lightweight design for one-handed use
  5. Rugged, durable design
  6. Automatic shutdown
  7. The battery is easy to replace


Write a review

Please login or register to review